Skip to content
STARCO  Fire Protection Engineers LLC Abu Dhabi · Since 2013 Company profile (PDF)
PO Box 499 Abu Dhabi, UAE info@starcofire.com +971-2 666 0466 Fax +971-2 666 0744
Fire detection and alarm

Eaton | Menvier

Eaton | Menvier

STARCO supplies, installs and commissions the Eaton Menvier addressable fire detection range across commercial, government, education and healthcare projects in Abu Dhabi and the wider UAE.

The range covers everything from a single-loop panel in a small building to a fault-tolerant networked system spanning a campus, and is certified to EN 54-2 and EN 54-4 with LPCB approval. We hold the range on our approved equipment list and carry out the design, installation, testing and commissioning as part of a single fire protection package.

Ranges we supply

Addressable control panels

One to four loop addressable panels with a 7-inch colour touchscreen and modular card architecture, so a system can be expanded as a building changes. Fault-tolerant ring networking means a single cable fault does not take communication down. EN 54-2 and EN 54-4 certified, LPCB approved.

  • Eaton | Menvier xDetect 2 / 4 loop — MXD01020 · MXD01040
    xDetect 2 / 4 loop — MXD01020 · MXD01040
  • Eaton | Menvier xDetect Mini 1–2 loop — MXD02002
    xDetect Mini 1–2 loop — MXD02002

Intelligent addressable sensors

Optical smoke, photo-thermal and multi-mode heat sensors on a common mounting base, each with an integral short circuit isolator and 360° indication. Sensor type is selected per area — optical for slow smouldering fires, heat where dust, steam or fumes would cause false alarms.

  • Eaton | Menvier Optical smoke — MAP820
    Optical smoke — MAP820
  • Eaton | Menvier Photo-thermal — MAOH850
    Photo-thermal — MAOH850
  • Eaton | Menvier Multi-mode heat — MAH830
    Multi-mode heat — MAH830
  • Eaton | Menvier Common base — MAB800
    Common base — MAB800

Duct smoke detection

Duct probe housings that sample air inside ventilation ductwork, so smoke carried through an air handling system is detected and the plant shut down before it is distributed through the building.

  • Eaton | Menvier Duct probe — MDP201
    Duct probe — MDP201

Sounders, beacons and call points

Addressable sounder bases, sounder beacons and manual call points on the same loop as the detection, including weatherproof IP66 units for external and plant areas. Tone and volume are set from the panel rather than at the device.

  • Eaton | Menvier Sounder base — MAS850
    Sounder base — MAS850
  • Eaton | Menvier Weatherproof sounder beacon — MASB860WP
    Weatherproof sounder beacon — MASB860WP
  • Eaton | Menvier Call points — MBG813 · MBG817 weatherproof
    Call points — MBG813 · MBG817 weatherproof

Interfaces, remote indicators and loop accessories

Micro input and output units that bring plant onto the fire alarm loop — monitoring sprinkler flow switches and auxiliary panels, and switching HVAC shutdown, fire door release and fan control. Remote indicators for detectors concealed above ceilings or inside rooms that are normally locked, plus the loop, sounder, I/O and network cards that configure a panel to a particular building.

  • Eaton | Menvier Single channel input unit — MMIM
    Single channel input unit — MMIM
  • Eaton | Menvier Single channel output unit — MMOM
    Single channel output unit — MMOM
Conventional remote indicator — DIR301 Loop connected remote indicator — MRIAD Loop, sounder, I/O and network cards — EFXD series

Emergency voice communication

Two-way fire telephone and disabled refuge communication to BS 5839 Part 9. The VoCALL 5 master unit at the fire control point talks to up to five outstations, emergency assist alarms or jack plates, wired radially in two-core fire-rated cable; firefighters plug a roaming handset into the jack plate on each floor.

  • Eaton | Menvier VoCALL 5 master unit — EFVCC5
    VoCALL 5 master unit — EFVCC5
  • Eaton | Menvier Roaming handset and jack plate — CFVCRHS
    Roaming handset and jack plate — CFVCRHS

Disabled toilet alarm

A stand-alone two-wire emergency assist alarm for accessible toilets, bathrooms and hotel rooms — dual-loop pull cord, over-door indicator with high-output blue light and buzzer, and a reset plate with tactile braille signage.

  • Eaton | Menvier Emergency assist alarm kit — CFEAPULLKIT
    Emergency assist alarm kit — CFEAPULLKIT

Eaton | Menvier is a trademark of Eaton. STARCO Fire Protection Engineers supplies, installs and commissions this equipment; product specifications and model codes are the manufacturer’s and are subject to change.